Indiana residential appliance installer license prep class instal the new version for windows3/20/2024 ![]() ![]() The discharge shall be directed away from the building. ![]() Power exhauster terminations shall be located not less than 10 feet (3048 mm) from lot lines and adjacent buildings.The vent termination shall not be mounted directly above or within 3 feet (914 mm) horizontally of an oil tank vent or gas meter.The bottom of the vent terminal shall be located not less than 12 inches (305 mm) above finished ground level.The vent termination point shall be located not closer than 3 feet (914 mm) to an interior corner formed by two walls perpendicular to each other.The vent terminal shall be located not less than 4 feet (1219 mm) below, 4 feet (1219 mm) horizontally from, or 1 foot (305 mm) above any door, window or gravity air inlet into a dwelling.The vent terminal shall be located not less than 3 feet (914 mm) above a forced air inlet located within 10 feet (3048 mm). Installer Certificate Program: Implemented in 2005 and revamped in 2010 to include continuing education in coordination with the new Indiana State Rule 410 IAC 6-8-3 effective Novemand most recently updated in May 2014.Mechanical draft systems shall comply with UL 378 and shall be installed in accordance with their listing, the manufacturer's instructions and, except for direct-vent appliances, the following requirements: ![]()